Stainless Steel High Velocity Relief Valve
High velocity relief valve is also called pressure/vacuum valve (P/V valve).It is widely used in the relief system of the oil tanker and the chemical tanker,It is not only for ensuring the safety of the cargo oil tank and avoiding over-pressure or low- pressure, but also for controlling the fire, the danger of explosion and the releasing of the noxious gas.It also pays more attention on its practicability; provides the safest high-velocity relief valve with a good price.
Overview
Basic structure of the DF high-velocity relief valve

Table 1 — Dimensions (mm)
| Type | DN | Pipe diameter | D2 | D1 | D | L | H | Assembly holes |
|---|---|---|---|---|---|---|---|---|
| DF250 | DN250 | ≥250 mm | 320 | 350 | 395 | 485 | 860 | 12 × Φ22 |
| DF200 | DN200 | ≥200 mm | 258 | 295 | 340 | 455 | 850 | 8 × Φ18 |
| DF150 | DN150 | ≥150 mm | 202 | 225 | 265 | 350 | 710 | 8 × Φ18 |
| DF125 | DN125 | ≥125 mm | 178 | 200 | 240 | 340 | 665 | 8 × Φ18 |
| DF100 | DN100 | ≥100 mm | 148 | 170 | 210 | 295 | 565 | 4 × Φ18 |
| DF80 | DN80 | ≥80 mm | 128 | 150 | 190 | 285 | 535 | 4 × Φ18 |
| DF65 | DN65 | ≥65 mm | 110 | 130 | 160 | 260 | 485 | 4 × Φ14 |
| DF50 | DN50 | ≥50 mm | 90 | 110 | 140 | 260 | 485 | 4 × Φ14 |
Remarks Flange standard: GB2501-89. For DN50–DN150 the nominal pressure is 0.6 MPa;for DN200 and DN250 the nominal pressure is 1.6 MPa (equivalent to ISO 2084-1974 and ISO 2441-1975).
Table 2 Main parts and materials
| serial No. | parts | quantity | material | parts over 10kg | remark |
|---|---|---|---|---|---|
| 1 | P-valve base | 1 | ZG200-400 | DN100-DN250 | |
| 2 | P-valve seat | 1 | 0Cr18Ni9 | DN200、DN250 | |
| 3 | P-valve upper body (A) | 1 | ZG200-400 | DN200、DN250 | |
| 4 | P-valve upper body (B) | 1 | ZG200-400 | DN150-DN250 | |
| 5 | P-valve disc (conducting machine) | 1 | 0Cr18Ni9 | no nothing | |
| 6 | matching block | 1 | 0Cr18Ni9 | no nothing | |
| 7 | P-valve pole | 1 | 0Cr18Ni9 | no nothing | |
| 8 | Jacking shaft | 1 | 0Cr18Ni9 | no nothing | |
| 9 | Lifting cam | 1 | 0Cr18Ni9 | no nothing | |
| 10 | Positioning plate | 1 | 0Cr18Ni9 | no nothing | GM parts |
| 11 | Lifting handle | 1 | 0Cr18Ni9 | no nothing | |
| 12 | Bushing | 1 | 0Cr18Ni9 | no nothing | choose to use |
| 13 | Nameplate | 1 | 0Cr18Ni9 | no nothing | GM parts |
| 14 | Lifting lever | 1 | 0Cr18Ni9 | no nothing | |
| 15 | V-valve body | 1 | ZG200-400 | no nothing | |
| 16 | V-valve disc | 1 | ZG200-400 | no nothing | |
| 17 | V-valve seat | 1 | 0Cr18Ni9 | no nothing | |
| 18 | small flame screen spacer ring | 1 | 0Cr18Ni9 | no nothing | |
| 19 | flame screen (30 mesh) | 2 | 00Cr17Ni14Mo2 | no nothing | use for both the top and the bottom |
| 20 | big flame screen spacer ring | 1 | ZG200-400 | no nothing | |
| 21 | flame screen gland | 1 | ZG200-400 | no nothing | |
| 22 | air-removal cover or V-valve cover | 1 | ZG200-400 | no nothing | choose to use |
Remarks: The shipowner may choose cast steel, cast 304, cast 304L or cast 316L.A cargo-compatible material shall be selected when the valve is used on chemical tankers.Internal materials shall be equal to or one grade higher than the body material.For chemical tankers, the material shall be equivalent to the hull material.
Table 3 Main technical parameters
| specification | setting opening pressure (kPa) | Rated working pressure (kPa) | flow rate(m³/h) | MESG mm | pressure valve exit velocity (m/s) | |||
|---|---|---|---|---|---|---|---|---|
| pressure valve | vacuum valve | pressure valve | vacuum valve | pressure valve | vacuum valve | |||
| DF50 | 14.0-20.0 | -3.5~-7.0 | 21.0 | -7.0 | >300 | >300 | ≥0.65 | >30 |
| DF65 | 14.0-20.0 | -3.5~-7.0 | 21.0 | -7.0 | >400 | >400 | ≥0.65 | >30 |
| DF80 | 14.0-20.0 | -3.5~-7.0 | 21.0 | -7.0 | >600 | >500 | ≥0.65 | >30 |
| DF100 | 14.0-20.0 | -3.5~-7.0 | 21.0 | -7.0 | >800 | >600 | ≥0.65 | >30 |
| DF125 | 14.0-20.0 | -3.5~-7.0 | 21.0 | -7.0 | >1000 | >800 | ≥0.65 | >30 |
| DF150 | 14.0-20.0 | -3.5~-7.0 | 21.0 | -7.0 | >2500 | >2000 | ≥0.65 | >30 |
| DF200 | 14.0-20.0 | -3.5~-7.0 | 21.0 | -7.0 | >3000 | >3000 | ≥0.65 | >30 |
| DF250 | 14.0-20.0 | -3.5~-7.0 | 21.0 | -7.0 | >3500 | >3000 | ≥0.65 | >30 |
Specification of High Velocity Relief Valve
| Nominal Diameter | Body Material | Product Inspection Standard | The Opening Pressure on the Oil Tank | The Opening Pressure on the Chemical Tank | Flange Standard |
|---|---|---|---|---|---|
| DN50 | Cast Steel/ SUS304/ SUS304L/ SUS316L | IMO MSC/Circ.677/ 1009-ISO 15364 | -3.5 Kpa~~14Kpa (-0.0035 Mpa~~0.014Mpa) | -3.5 Kpa~~20Kpa (-0.0035 Mpa~~0.020Mpa) | GB/JIS/DIN/ ANSI etc |
| DN65 | |||||
| DN80 | |||||
| DN100 | |||||
| DN125 | |||||
| DN150 | |||||
| DN200 | |||||
| DN250 |
Testing
The original product information lists fire resistance, re-burning, freezing, corrosion resistance and flow tests conducted in a laboratory approved by the competent national authority. It also lists CCS and other classification approvals. Please confirm the applicable certificate and model scope when ordering.
Why this valve
It drops in, and nothing has to be set.
Delivered assembled, tested and set to the design pressure — installation is the flange bolting and nothing else. No re-adjustment on board, no commissioning procedure to argue about with the surveyor.
Serviced from the top, in minutes.
The valve opens from above and stays on the pipeline. The pressure valve outlet can be cleaned without dismantling at all — put the stem in the open position and flush. Six-month inspection, annual strip-down.
Still have a question? Write it to us as it is.
No form to fill in and no sales sequence. Ask in your own words — in English or Chinese — and it goes to the person who handles the technical side, not to a mailbox that nobody reads.Whether you are replacing a valve on an existing vessel, specifying for a newbuilding, or holding spares for a fleet, tell us which of the three it is and send whatever you already have. What helps most differs by case:
Three things speed up an answer more than anything else:
A photo of the old valve's flange, with a tape measure across the bolt circle — that alone is usually enough for us to confirm whether ours drops straight in.we will check them line by line against our dimension table and confirm the match before you commit.(for replaceing a valve)
Tank capacity and maximum loading rate — enough for us to tell you which size the venting capacity points to.
The cargo list — if any parcel can crystallise when its vapour condenses, we will tell you before you order rather than after the valve jams.
In return you get a dimensional check against your existing valve, a setting recommendation for your ship type, and a written statement of which certificates we can supply for your class . If something is outside what we can do, we will say so instead of quoting anyway.