JIS F7211 Tube Glass Level Gauge With 5K Valves Shipboard

JIS F7211 Tube Glass Level Gauge With 5K Valves Shipboard


Item

Description

Product Name

JIS F7211 Tube Glass Level Gauge With 5K Valves Shipboard

Certificates

ABS, LR, BV, DNV, RINA, CCS

FOB Price

Get Latest Price Now

Warranty

12 months (unless otherwise specified)

Place of Origin

China


Overview

1. SCOPE

This standard specifies the tube glass type level gauges with 5K valves (hereafter referred to as "level gauges") used for water tanks, oil tanks on vessels not subject to SOLAS, and low-pressure vessels, with a maximum working pressure of 0.49 MPa.

2. NORMATIVE REFERENCES

The following standards, by being cited in this standard, form a part of this standard. The latest editions (including amendments) of these referenced standards apply.

3. TYPES

The types of level gauges are classified into the following 5 types according to the shape of the upper body: Type A (for steel pipe), Type A' (for copper pipe), Type B, Type C, and Type D.

4. CONSTRUCTION, SHAPE, AND DIMENSIONS

Upper BodyType A0.75

Type B0.82

Type C1.38

Type D0.14
Valve Body-0.81
Lower Body-1.34

5. MATERIALS

Part No.Part NameMaterial
1Type A Upper BodyJIS H 5120 CAC406
2NippleSteel pipe: JIS G 3101 SS400; Copper pipe: JIS H 5120 CAC201 or JIS H 3250 C1100BD
3Packing WasherJIS H 5120 CAC406
4Packing Washer NutJIS H 3250 C3771BD
5Hexagon NutJIS G 3101 SS400 or JIS H 5120 CAC406
6PackingPer JIS F 7102
7GasketPer JIS F 7102
8GasketPer JIS F 7102
9PlugJIS H 5120 CAC406 or JIS H 3250 C3771BD
10Valve BodyJIS H 5120 CAC406
11Type B Upper BodyJIS H 5120 CAC406
12Type C Upper BodyJIS H 5120 CAC406
13Lower BodyJIS H 5120 CAC406
14StemJIS H 3250 C3771BD or C3771BE
15Packing WasherJIS H 5120 CAC406
16Packing Washer NutJIS H 3250 C3771BD
17Handle WheelJIS G 5501 FC200
18Hexagon NutJIS H 3250 C3771BD
19Spring WasherJIS G 3506 SWRH62B
20Split PinJIS H 3260 C2600W
21PackingPer JIS F 7102
22PackingPer JIS F 7102
23Type D Upper FittingJIS H 3100 C2600P or JIS H 3250 C3771BD
24Wire MeshJIS H 3260 C2600W

6. INSPECTION

The inspection of level gauges shall be carried out in accordance with JIS F 7400, performing the following tests a) to e):
a) Material inspection
b) External appearance inspection
c) Dimensional inspection
d) Assembly inspection
e) Hydraulic test at the following test pressures:

  1. Water pressure test for upper body, lower body, and valve body: 0.75 MPa

  2. Seat water leakage test: 0.55 MPa

DIMENSIONS FOR H AND H1 IN THE CASE OF TOUGHENED GLASS

DesignationFWG 5-A1 and FWG 5-B




FWG 5-C




FWG 5-D

Number of Hand Valves0123450123450

Number of Glass Tubes1234561234561

Length per glass tube L














200Protective fitting length175-----------210
300
275-----------310
350
325650975130016251950340665990131516401965-
400
37575011251500187522503907651140151518902265-
450
42585012751700212525504408651290171521402565-
500
47595014251900237528504909651440191523902865-
550
5251050157521002625315054010651590211526403165-
600
5751150172523002875345059011651740231528903465-
600 (l)
5406251250187525003125375064012651890251531403765-
Calculated Mass (kg)2.093.712.163.782.724.341.48









Contact Us